Invite others to add a comment
Add a comment
Hide comments
Sign up for a free account. Ask your own questions and make confident decisions.
Close

TrueBeam Beam Utilization - meddos

Q1 w

What percentage of your patients are treated with the following beams?

  • Answered: 11
  • Skipped: 0
100.00%
11
81.82%
9
81.82%
9
63.64%
7
15MV or 18MV
72.73%
8
Q2 w

Please add any comments on the use of 6MV and/or 6FFF.

  • Answered: 8
  • Skipped: 3
Use first
6/5/2019 11:35 AM
I plan lung patients. About 60% are SBRT so I use the 6FFF. For the other ones are use 6MV.
6/5/2019 08:32 AM
We use 6MV for larger lesions and 6fff for smaller, high dose tumors especially SBRT
6/5/2019 03:13 AM
FFF not commissioned
6/4/2019 07:54 PM
we don't have/utilize 6FFF
6/4/2019 07:10 PM
6FFF use only for SBRT lung and SRS
6/4/2019 06:23 PM
6FFF sbrt/srs only
6/4/2019 06:14 PM
6 FFF for SRS MLC/cones and SBRT
6/4/2019 06:07 PM
Q3 w

Please add any comments on the use of 10MV and/or 10FFF.

  • Answered: 6
  • Skipped: 5
For large patients
6/5/2019 11:35 AM
I will use a 10 MV beam if there is more than 10 cm of soft tissue before that beam hits air in lung.
6/5/2019 08:32 AM
10MV is the bomb, Clinac 18 had it right in 1976. 10fff is great for SBRT outside lung
6/5/2019 03:13 AM
We love using 10FFF for lung SBRTs. We do however only bump up our dose rate to 800.
6/4/2019 07:10 PM
10MV for SRS and SBRT only
6/4/2019 06:23 PM
10 FFF srs only
6/4/2019 06:14 PM
Q4 w

Please add any comments on the use of 15MV or 18MV.

  • Answered: 3
  • Skipped: 8
I treat lung patients so I do not use 15MV or 18 MV.
6/5/2019 08:32 AM
Could do without (easily)
6/5/2019 03:13 AM
All pelvis tx
6/4/2019 06:23 PM
Q5 w

Please add any other comments on the topic.

  • Answered: 2
  • Skipped: 9
We have matching TrueBeams, in case and machine goes down, we can move patients between machines. But only one of them has 10 FFF so we don’t use it. Because a patient with 10 FFF and the machine goes down cannot be treated.
6/5/2019 08:32 AM
Interesting how we can get so much more yield at 10fff (2400 MU/min) than 6fff(1400MU/min)
6/5/2019 03:13 AM